The program allows determination of the required amount of shear reinforcement form by stirrups and bends, respectively.

First, the program computes the ultimate shear strength in a given section - the shear force transmitted by concrete Vc and the maximum allowable shear force Vmax.

where:

for cross-sections with a height smaller than 200mm

vc is computed according to the following formulas for cross-sections with a height greater than 400mm, intermediate values are obtained using a linear interpolation method.

where ρw is the degree of reinforcement and fc' is limited to value 50MPa.

As for stirrups, the necessary reinforcement area is given by:

As for bends, the necessary reinforcement area is given by: